Number: A1TH090590U581
Subject: Errors Using 286 v2.15a Bridge Connected to v2.15c Server
Date: January 28, 1991
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
PROBLEM: A client was using a Cubix board in a protected mode
nondedicated bridge with a NE2000. The bridge was working
under NetWare 286 v2.15a. He upgraded the file server to
v2.15c (bridge was left at v2.15a). The bridge would load
fine, but when he tried to login he would get an error
reading from file server. He had the latest drivers.
SOLUTION: We regenerated the bridge with the v2.15c software and
everything worked.
(X) This information was verified verbally